Applicaiton Required

CBIS-DDSM

Breast Cancer

This CBIS-DDSM (Curated Breast Imaging Subset of DDSM) is an updated and standardized version of the Digital Database for Screening Mammography (DDSM). The DDSM is a database of 2,620 scanned film mammography studies. It contains normal, benign, and malignant cases with verified pathology information. The scale of the database along with ground truth validation makes the DDSM a useful tool in the development and testing of decision support systems. The CBIS-DDSM collection includes a subset of the DDSM data selected and curated by a trained mammographer. The images have been decompressed and converted to DICOM format. Updated ROI segmentation and bounding boxes, and pathologic diagnosis for training data are also included. Published research results from work in developing decision support systems in mammography are difficult to replicate due to the lack of a standard evaluation data set; most computer-aided diagnosis (CADx) and detection (CADe) algorithms for breast cancer in mammography are evaluated on private data sets or on unspecified subsets of public databases. Few well-curated public datasets have been provided for the mammography community. These include the DDSM, the Mammographic Imaging Analysis Society (MIAS) database, and the Image Retrieval in Medical Applications (IRMA) project. Although these public data sets are useful, they are limited in terms of data set size and accessibility.

For example, most researchers using the DDSM do not leverage all its images for a variety of historical reasons. When the database was released in 1997, computational resources to process hundreds or thousands of images were not widely available. Additionally, the DDSM images are saved in non-standard compression files that require the use of decompression code that has not been updated or maintained for modern computers. Finally, the ROI annotations for the abnormalities in the DDSM were provided to indicate a general position of lesions, but not a precise segmentation for them. Therefore, many researchers must implement segmentation algorithms for accurate feature extraction. This causes an inability to directly compare the performance of methods or to replicate prior results. The CBIS-DDSM collection addresses that challenge by publicly releasing an curated and standardized version of the DDSM for evaluation of future CADx and CADe systems (sometimes referred to generally as CAD) research in mammography.

For scientific inquiries about this dataset, please contact Dr. Daniel Rubin, Department of Biomedical Data Science, Radiology, and Medicine, Stanford University School of Medicine (dlrubin@stanford.edu). A manuscript describing the dataset in detail is under review in Scientific Data and will be linked here when published.

Data and Resources

Additional Info

Field Value
Last Updated December 3, 2019, 11:32 (CST)
Created May 30, 2018, 16:17 (CST)

推薦資料集:


  • insight_test_9442

    Payment instrument Free
    Update frequency Irregular
  • 臺北市婦幼安全警示地點

    Payment instrument Free
    Update frequency Irregular
    「婦幼安全警示地點」係指近三年來曾有民眾通報或曾發生兩造當事人為陌生關係婦幼被害案件(包括刑法妨害性自主罪、第234條公然猥褻罪、第315條之1妨害秘密罪、性騷擾防治法第25條性騷擾罪等性別暴力犯罪)於道路、公園及廣場之公共場所、路段,經警察機關依轄區特性評估確為應提醒婦女、兒童及少年等弱勢族群注意安全,防範被害之地點。
  • 1836-01-22-2 臺中市身心障礙者保護通報類型按障礙類別及等級別分

    Payment instrument Free
    Update frequency Irregular
    一、統計標準時間:第1季以1至3月、第2季以1至6月、第3季以1至9月、第4季以1至12月之事實為準。 二、分類標準:橫項依「通報類型」及「障礙等級」分;縱項依「障礙類別」及「性別」分。
  • 108年度統計調查單位數

    Payment instrument Free
    Update frequency Irregular
    提供108年度統計調查單位數
  • 台電年度委託研究主題及研究重點

    Payment instrument Free
    Update frequency Irregular
    依據經濟部所屬各事業科學與技術類委託研究計畫作業規定,公告本公司年度委託研究之主題及重點,供產學界參與委託研究