Applicaiton Required

Head-and-neck squamous cell carcinoma patients with 3D CT taken during pre-treatment, mid-treatment, and post-treatment (HNSCC-3DCT-RT)

Researchers will have the unique opportunity to visualize how head-and-neck squamous cell carcinoma (HNSCC) patients’ 3D CT image data changes with radiotherapy between pre-treatment, mid-treatment, and post-treatment. They will also have the advantage to receive additional information such as a) photon energy, b) number of arcs for volumetric modulated arc radiotherapy (VMAT) therapy, c) tumor volume and location, d) CT-to-density table, e) treatment related toxicities for parotid glands and oral cavity, f) patient age and weight, patient chemotherapy medication, g) prior surgery, h) performance status, i) histology, j) disease stage, k) number of targets, l) organs at risk, and m) other structures delineated on the CT image. This data collection contains three dimensional high-resolution (3D) fan-beam CT scans collected during pre-treatment, mid-treatment, and post-treatment using a Siemens 16-slice CT scanner with standard clinical protocol for 31 head-and-neck squamous cell carcinoma (HNSCC) patients. Patients underwent radiotherapy treatment to a total dose of 58-70 Gy, using daily 2-2.20 Gy, fractions for 30-35 fractions. The pre-treatment planning CT scans were performed with a median of 13 days (range: 2-27) before treatment, the mid-treatment CT was performed at fraction 17 (range: 8-26), and the post-treatment CT around fraction 30 (range: 26th fraction - 21 weeks post treatment). In addition to the imaging data, the data sets contain contours of anatomical structures for radiotherapy. The contours were generated by the attending radiation oncologists for treatment planning purposes, and subsequently treatment plans were generated with Eclipse® (Varian Medical Systems, Inc., Palo Alto, CA) treatment planning system. In addition to CT image data, included are: a) photon energy, b) number of arcs for volumetric modulated arc radiotherapy (VMAT) therapy, c) tumor volume and location, d) CT-to-density table, e) treatment related toxicities for parotid glands and oral cavity, f) patient age and weight, patient chemotherapy medication, g) prior surgery, h) performance status, i) histology, j) disease stage, k) number of targets, l) organs at risk, and m) other structures delineated on the CT image.

All patients were recruited according to the following criteria. Inclusion: i) patients had histologically confirmed head-and-neck tumors, ii) were treated with definitive radiation therapy or concurrent chemoradiation therapy, iii) patients treated with post-operative radiation therapy, for whom the gross tumor volume (GTV) or the resection cavity were visible on CT, such that it could be delineated as a target for radiotherapy, iv) patients were informed of the investigational nature of this study and were able to understand and to sign a written informed consent document.

Exclusion: i) pregnant or nursing women were not eligible to participate, ii) women of reproductive potential must have been offered a pre-treatment pregnancy test and informed of the need to practice an effective contraceptive method, iii) patients younger than 18 years, and iv) patients whose size and weight would not allow CT scanning.

Data and Resources

Additional Info

Field Value
Last Updated December 3, 2019, 14:14 (CST)
Created October 16, 2018, 08:40 (CST)

推薦資料集:


  • 高雄市三民區109年度土地段名代碼表

    Payment instrument Free
    Update frequency Irregular
    提供高雄市三民區土地段名代碼表
  • 宜蘭縣政府財政稅務局106年視訊服務件數統計表

    Payment instrument Free
    Update frequency Irregular
    提供宜蘭縣政府財政稅務局106年視訊服務件數統計表
  • 愛心溫度計-行業別電子發票開立統計-資料集

    Payment instrument Free
    Update frequency Irregular
    依年月和行業別維度統計電子發票開立張數。
  • 捐助經費分析表

    Payment instrument Free
    Update frequency Irregular
    本會相關預算資料
  • 108年度宜蘭縣早期療育服務通報轉介中心

    Payment instrument Free
    Update frequency Irregular
    108年度宜蘭縣社福相關資料