Applicaiton Required

Prostate Fused-MRI-Pathology

This collection comprises a total of 28 3 Tesla T1-weighted, T2-weighted, Diffusion weighted and Dynamic Contrast Enhanced prostate MRI along with accompanying digitized histopathology (H&Estained) images of corresponding radical prostatectomy specimens. The MRI scans also have a mapping of extent of prostate cancer on them [1]. Each surgically excised prostate specimen was originally sectioned and quartered resulting in 4 slides for each section. Each of these individual slides was digitized at 20x magnification using an Aperio slide scanner resulting in a set of 4 .svs images. Each of the 4 .svs images were then digitally stitched together to constitute a pseudo-whole mount section (.tiff) using the program in [2]. Annotations of cancer presence on the pseudo-whole mount sections were made by an expert pathologist. Slice correspondences were established between the individual T2w MRI and stitched pseudo-whole mount sections by the program in [3] and checked for accuracy by an expert pathologist and radiologist. Deformable co-registration [4] was employed to spatially co-registered the corresponding radiologic and histopathologic tissue sections to map disease extent onto the corresponding MRI scans. Data collection and analysis was provided by Anant Madabhushi, PhD, Case Western Reserve University and Michael D. Feldman, MD, PhD, Hospital at the University of Pennsylvania. This work was supported by NIH R01CA136535.

References Singanamalli, A, Sparks, R, Rusu, M, Shih, N, Ziober, A, Tomaszewski, J, Rosen, M, Feldman, M, Madabhushi, A, “Identifying in vivo DCE MRI markers associated with Microvessel Architecture and Gleason Grades of Prostate Cancer—Preliminary Findings”, Journal of Magnetic Resonance Imaging, doi: 10.1002/jmri.24975. [Epub ahead of print] (PMID:26110513). Toth, R, Feldman, M, Yu, D, Tomaszewski, J, Madabhushi, A, “Histostitcher™: An Informatics Software Platform for Reconstructing Whole-Mount Prostate Histology using the Extensible Imaging Platform (XIP™) Framework,” Journal of Pathology Informatics, vol. 5, pg. 8, 2014 (PMID: 24843820, PMCID: PMC4023035). Xiao, G, Bloch, N, Chappelow, J, Genega, E, Rofsky, N, Lenkinsky, R, Tomaszewski, J, Feldman, M, Rosen, M, Madabhushi, A, “Determining Histology-MRI Slice Correspondences for Defining MRI-based Disease Signatures of Prostate Cancer,” Special Issue of Computerized Medical Imaging and Graphics on Whole Slide Microscopic Image Processing, vol. 35[7-8], pp. 568-78, 2011 (PMID: 21255974). Chappelow, J, Bloch, N., Rofsky, N, Genega, E, Lenkinski, R, DeWolf, W, Madabhushi, A, “Elastic Registration of Multimodal Prostate MRI and Histology via Multi-Attribute Combined Mutual Information,” Medical Physics, vol. 38[4], pp. 2005-2018, 2011 (PMID: 21626933).

Data and Resources

Additional Info

Field Value
Last Updated December 3, 2019, 14:15 (CST)
Created October 15, 2018, 20:51 (CST)

推薦資料集:


  • 新北市105年公告土地現值及公告地價-中和區

    Payment instrument Free
    Update frequency Irregular
    為推動不動產買賣資訊透明化,建立便利親和的網路查詢平台,新北市政府地政局開放公告土地現值資料給予民眾,可多多利用下載。公告土地現值資料量較大,請參考資料使用說明以及常見問答後再行取得資料。-中和區
  • insight_test_8263

    Payment instrument Free
    Update frequency Irregular
  • 經濟部能源局_電扇節能標章有效獲證資訊

    Payment instrument Free
    Update frequency Irregular
    提供電扇能源效率相關資訊,作為消費者選購產品之參考,使消費者在選購產品時,能以簡易之方式分辨節能產品。經濟部能源局透過節能標章驗證制度,提供我國高效率產品之驗證,通過節能標章驗證的產品,代表其為同類型產品前30%之高能源效率產品。
  • 財政部北區國稅局首長傾聽作業要點

    Payment instrument Free
    Update frequency Irregular
    為展現親民、便民及愛民之服務效能,主動發掘稅務問題,解決納稅義務人納稅疑義並廣納建言,以提升稅務行政績效,建構直接與納稅義務人面對面溝通機制,特訂定本要點。
  • 居家護理機構

    Payment instrument Free
    Update frequency Irregular
    居家護理機構