Applicaiton Required

4D-Lung

This data collection consists of images acquired during chemoradiotherapy of 20 locally-advanced, non-small cell lung cancer patients. The images include four-dimensional (4D) fan beam (4D-FBCT) and 4D cone beam CT (4D-CBCT). All patients underwent concurrent radiochemotherapy to a total dose of 64.8-70 Gy using daily 1.8 or 2 Gy fractions. 4D-FBCT images were acquired on a 16-slice helical CT scanner (Brilliance Big Bore, Philips Medical Systems, Andover, MA) as respiration-correlated CTs with 10 breathing phases (0 to 90%, phase-based binning) and 3 mm slice thickness. 4D-FBCT images were acquired during simulation, prior to therapy, and used for therapy planning. In 14 of the 20 subjects, 4D-FBCTs were also acquired on the same scanner weekly during therapy. 4D-CBCT images were acquired on a commercial CBCT scanner (On-Board Imager™, Varian Medical Systems, Inc.). An external surrogate (Real-time Position Management, Varian Medical Systems, Inc.) was integrated into the CBCT acquisition system to stamp each CBCT projection with the surrogate respiratory signal through in-house software and hardware tools. Approximately 2500 projections were acquired over a period of 8-10 minutes in half-fan mode with half bow-tie filter. The technique was 125 kVp, 20 mA, and 20 ms in a single 360° slow gantry arc. Using the external surrogate, the CBCT projections were sorted into 10 breathing phases (0 to 90%, phase-based binning) and reconstructed with an in-house FDK reconstruction algorithm.

Audio-visual biofeedback was performed for all 4D-FBCT and 4D-CBCT acquisitions in all subjects. A single Radiation Oncologist delineated targets and organs at risk in all 4D-FBCT and a limited number of 4D-CBCT images, on all 10 phases per scan. Seven of the subjects had gold coils implanted as fiducial markers in or near the tumor.

For questions and information regarding this dataset, please contact Geoff Hugo, gdhugo@wustl.edu.

Data collection and analysis was supported by NIH P01CA116602.

データとリソース

このデータセットにはデータがありません

追加情報

フィールド
最終更新 12月 3, 2019, 14:29 (CST)
作成日 2月 14, 2019, 10:19 (CST)

推薦資料集:


  • 地區年齡性別統計表-拉薩熱

    Payment instrument Free
    Update frequency Irregular
    2003年起各地區、各年齡層、性別之病例數統計表(疾病名稱:拉薩熱,日期種類:發病日,病例種類:確定病例,感染來源:本土、境外移入)
  • 漁會會員勞保月負擔保險費金額表

    Payment instrument Free
    Update frequency Irregular
    提供漁會及所屬會員查詢每月個別應負擔保險費
  • 新北市電動機車充電站-三峽區

    Payment instrument Free
    Update frequency Irregular
    新北市電動機車充電站。-三峽區
  • 國際收支簡表(季資料)

    Payment instrument Free
    Update frequency Irregular
    國際收支簡表(季資料)
  • 新北市固定式測速照相-新店區

    Payment instrument Free
    Update frequency Irregular
    新北市政府警察局所提供的固定測速照相主要提供欄位包含行政區、設置位置、速限、取締項目。-新店區