Applicaiton Required

4D-Lung

This data collection consists of images acquired during chemoradiotherapy of 20 locally-advanced, non-small cell lung cancer patients. The images include four-dimensional (4D) fan beam (4D-FBCT) and 4D cone beam CT (4D-CBCT). All patients underwent concurrent radiochemotherapy to a total dose of 64.8-70 Gy using daily 1.8 or 2 Gy fractions. 4D-FBCT images were acquired on a 16-slice helical CT scanner (Brilliance Big Bore, Philips Medical Systems, Andover, MA) as respiration-correlated CTs with 10 breathing phases (0 to 90%, phase-based binning) and 3 mm slice thickness. 4D-FBCT images were acquired during simulation, prior to therapy, and used for therapy planning. In 14 of the 20 subjects, 4D-FBCTs were also acquired on the same scanner weekly during therapy. 4D-CBCT images were acquired on a commercial CBCT scanner (On-Board Imager™, Varian Medical Systems, Inc.). An external surrogate (Real-time Position Management, Varian Medical Systems, Inc.) was integrated into the CBCT acquisition system to stamp each CBCT projection with the surrogate respiratory signal through in-house software and hardware tools. Approximately 2500 projections were acquired over a period of 8-10 minutes in half-fan mode with half bow-tie filter. The technique was 125 kVp, 20 mA, and 20 ms in a single 360° slow gantry arc. Using the external surrogate, the CBCT projections were sorted into 10 breathing phases (0 to 90%, phase-based binning) and reconstructed with an in-house FDK reconstruction algorithm.

Audio-visual biofeedback was performed for all 4D-FBCT and 4D-CBCT acquisitions in all subjects. A single Radiation Oncologist delineated targets and organs at risk in all 4D-FBCT and a limited number of 4D-CBCT images, on all 10 phases per scan. Seven of the subjects had gold coils implanted as fiducial markers in or near the tumor.

For questions and information regarding this dataset, please contact Geoff Hugo, gdhugo@wustl.edu.

Data collection and analysis was supported by NIH P01CA116602.

データとリソース

このデータセットにはデータがありません

追加情報

フィールド 値
最終更新 12月 3, 2019, 14:29 (CST)
作成日 2月 14, 2019, 10:19 (CST)

推薦資料集:


  • 高雄市網路成癮治療服務資源表

    Payment instrument Free
    Update frequency Irregular
    醫療/醫事機構、開診科別、門診/服務時間(如有異動,請依各醫療院所公告為準)、電話
  • AI CUP 2022農地作物現況調查影像辨識競賽-秋季賽_茭白筍影像訓練資料集

    Payment instrument Free
    Update frequency Irregular
    用於AI CUP 2022農地作物現況調查影像辨識競賽-秋季賽之訓練資料集,影像資訊來源為行政院農業委員會。
  • 105年度高雄市政府民政局執行台電公司促協金經費一覽表

    Payment instrument Free
    Update frequency Irregular
    促協金名稱、補助金額、補助地區、執行金額、補助對象及運用項目
  • 高雄市各區現住人口數年齡分組統計

    Payment instrument Free
    Update frequency Irregular
    高雄市各區現住人口數年齡分組統計資料
  • Applicaiton Required

    Android惡意程式分析資訊

    Payment instrument Free
    Update frequency Irregular
    Android malware的分析結果