Applicaiton Required

4D-Lung

This data collection consists of images acquired during chemoradiotherapy of 20 locally-advanced, non-small cell lung cancer patients. The images include four-dimensional (4D) fan beam (4D-FBCT) and 4D cone beam CT (4D-CBCT). All patients underwent concurrent radiochemotherapy to a total dose of 64.8-70 Gy using daily 1.8 or 2 Gy fractions. 4D-FBCT images were acquired on a 16-slice helical CT scanner (Brilliance Big Bore, Philips Medical Systems, Andover, MA) as respiration-correlated CTs with 10 breathing phases (0 to 90%, phase-based binning) and 3 mm slice thickness. 4D-FBCT images were acquired during simulation, prior to therapy, and used for therapy planning. In 14 of the 20 subjects, 4D-FBCTs were also acquired on the same scanner weekly during therapy. 4D-CBCT images were acquired on a commercial CBCT scanner (On-Board Imager™, Varian Medical Systems, Inc.). An external surrogate (Real-time Position Management, Varian Medical Systems, Inc.) was integrated into the CBCT acquisition system to stamp each CBCT projection with the surrogate respiratory signal through in-house software and hardware tools. Approximately 2500 projections were acquired over a period of 8-10 minutes in half-fan mode with half bow-tie filter. The technique was 125 kVp, 20 mA, and 20 ms in a single 360° slow gantry arc. Using the external surrogate, the CBCT projections were sorted into 10 breathing phases (0 to 90%, phase-based binning) and reconstructed with an in-house FDK reconstruction algorithm.

Audio-visual biofeedback was performed for all 4D-FBCT and 4D-CBCT acquisitions in all subjects. A single Radiation Oncologist delineated targets and organs at risk in all 4D-FBCT and a limited number of 4D-CBCT images, on all 10 phases per scan. Seven of the subjects had gold coils implanted as fiducial markers in or near the tumor.

For questions and information regarding this dataset, please contact Geoff Hugo, gdhugo@wustl.edu.

Data collection and analysis was supported by NIH P01CA116602.

Data and Resources

This dataset has no data

Additional Info

Field Value
Last Updated December 3, 2019, 14:29 (CST)
Created February 14, 2019, 10:19 (CST)

推薦資料集:


  • Applicaiton Required

    H11-M111_基於空間一致性與對比噪聲標註學習的免疫細胞浸潤分割模型

    Payment instrument Free
    Update frequency Irregular
    使用於肝臟發炎細胞之分割任務
  • 民營事業污染防治設備低利貸款要點及貸放情形

    Payment instrument Free
    Update frequency Irregular
    介紹民營事業污染防治設備低利貸款(第六期)貸款要點內容,包括資金額度、貸款對象、貸款範圍、辦理單位、貸款額度及利率等相關規定。
  • 臺北市兒童新樂園園區資訊

    Payment instrument Free
    Update frequency Irregular
    兒童新樂園園區營運時間及門票資訊、13項遊樂設施介紹、其他遊樂設施介紹、設施設備位置、園區美食商品、兒童劇場、樹蛙表演場、停車場資訊、大眾運輸轉乘資訊及開車路線資訊
  • 高雄市經濟案件與取締電玩攤販

    Payment instrument Free
    Update frequency Irregular
    高雄市經濟案件與取締電玩攤販資料
  • 新北市中醫一般科醫療機構

    Payment instrument Free
    Update frequency Irregular
    新北市中醫一般科醫療機構清單