Credence Cartridge Radiomics Phantom CT Scans

This collection consists of 17 CT scans of the Credence Cartridge Radiomics (CCR) phantom, which was designed for use in studies of texture feature robustness. The scans were acquired at four medical centers using each center’s chest protocol and were taken using GE (7 scans), Philips (5 scans), Siemens (2 scans), and Toshiba (3 scans) scanners. The CCR phantom has 10 cartridges, each with a unique texture, Fig 1. The first four cartridges are 3D printed ABS plastic with 20%, 30%, 40%, and 50% honeycomb fill, and they provide regular, periodic textures. The next three cartridges provide natural textures: sycamore wood, cork, and extra dense cork. A cartridges of shredded rubber particles provides textures similar to those of non-small cell lung cancer. The ninth cartridge is solid, homogenous acrylic and provides a minimal texture control. Finally, the 10th cartridge is 3D printed plaster has the highest electron density (400 – 600 HU) and is intended to more similar to bone.

In addition to the DICOM images for the 17 scans, this collection also contains two sets of contours as DICOM RT structure files. The first set provides 8x8x2 cm3 contours for each cartridge in each scan. The second set provides 16 adjacent 2x2x2 cm3 contours for each cartridge in each scan.

Researchers studying radiomics will be able to evaluate features for robustness across a variety of scanners. Features can be calculated using the researchers own software or third party software such as IBEX (imaging biomarker explorer). Related publications: http://journals.lww.com/investigativeradiology/Abstract/2015/11000/Measuring_Computed_Tomography_Scanner_Variability.3.aspx

The following paper was generated on different imaging modalities but the same phantom, this is a related but independent paper with a different set of authors: http://tinyurl.com/zm7tr7p

This data set was provided to TCIA by Authors: Mackin, Dennis; Fave, Xenia; Zhang, Lifei; Fried, David; Yang, Jinzhong; Taylor, Brian; Rodriguez-Rivera, Edgardo; Dodge, Cristina; Jones, Aaron Kyle; and Court, Laurence.

データとリソース

追加情報

フィールド
最終更新 12月 3, 2019, 14:19 (CST)
作成日 2月 14, 2019, 10:19 (CST)

推薦資料集:


  • 臺東縣農地重劃區105-108緊急農水路工程

    Payment instrument Free
    Update frequency Irregular
    臺東縣農地重劃區105-108緊急農水路工程
  • 歷年農藥檢測不合格業者名單

    Payment instrument Free
    Update frequency Irregular
    歷年農藥檢測不合格業者名單
  • 105年高雄市政府民政局APPS累計下載次數資料表

    Payment instrument Free
    Update frequency Irregular
    年份、月份、機關名稱、APP名稱、類型、累計下載次數
  • 桃園國際機場第一航廈各單位服務電話

    Payment instrument Free
    Update frequency Irregular
    本資料集提供桃園國際機場第一航廈各單位服務電話
  • 12-17歲過去一個月飲酒率

    Payment instrument Free
    Update frequency Irregular
    【資料來源】衛生福利部國民健康署及國家衛生研究院合辦「國民健康訪問調查」,該調查係利用面訪方式收集各類與國民健康狀況相關的調查資料,簡介請參見「國民健康訪問調查」網站(http://nhis.nhri.org.tw/)。...