Credence Cartridge Radiomics Phantom CT Scans

This collection consists of 17 CT scans of the Credence Cartridge Radiomics (CCR) phantom, which was designed for use in studies of texture feature robustness. The scans were acquired at four medical centers using each center’s chest protocol and were taken using GE (7 scans), Philips (5 scans), Siemens (2 scans), and Toshiba (3 scans) scanners. The CCR phantom has 10 cartridges, each with a unique texture, Fig 1. The first four cartridges are 3D printed ABS plastic with 20%, 30%, 40%, and 50% honeycomb fill, and they provide regular, periodic textures. The next three cartridges provide natural textures: sycamore wood, cork, and extra dense cork. A cartridges of shredded rubber particles provides textures similar to those of non-small cell lung cancer. The ninth cartridge is solid, homogenous acrylic and provides a minimal texture control. Finally, the 10th cartridge is 3D printed plaster has the highest electron density (400 – 600 HU) and is intended to more similar to bone.

In addition to the DICOM images for the 17 scans, this collection also contains two sets of contours as DICOM RT structure files. The first set provides 8x8x2 cm3 contours for each cartridge in each scan. The second set provides 16 adjacent 2x2x2 cm3 contours for each cartridge in each scan.

Researchers studying radiomics will be able to evaluate features for robustness across a variety of scanners. Features can be calculated using the researchers own software or third party software such as IBEX (imaging biomarker explorer). Related publications: http://journals.lww.com/investigativeradiology/Abstract/2015/11000/Measuring_Computed_Tomography_Scanner_Variability.3.aspx

The following paper was generated on different imaging modalities but the same phantom, this is a related but independent paper with a different set of authors: http://tinyurl.com/zm7tr7p

This data set was provided to TCIA by Authors: Mackin, Dennis; Fave, Xenia; Zhang, Lifei; Fried, David; Yang, Jinzhong; Taylor, Brian; Rodriguez-Rivera, Edgardo; Dodge, Cristina; Jones, Aaron Kyle; and Court, Laurence.

データとリソース

追加情報

フィールド
最終更新 12月 3, 2019, 14:19 (CST)
作成日 2月 14, 2019, 10:19 (CST)

推薦資料集:


  • 111年度新北市附屬單位預算資本計畫基金來源、用途及餘絀綜計表(預算案)

    Payment instrument Free
    Update frequency Irregular
    1.單位:新臺幣千元。2.各項欄位說明詳參新北市政府主計處網頁或電洽主計處查詢。
  • 金僑獎歷年獲獎名單

    Payment instrument Free
    Update frequency Irregular
    為拓展臺灣宏觀電視能見度,自2009年至2016年舉辦金僑獎向海內外華人徵求短片及照片,鼓勵僑胞以影像紀錄僑居記憶。
  • 新北市NewTaipei熱點-烏來區

    Payment instrument Free
    Update frequency Irregular
    新北市政府無線網路(NewTaipei)熱點資訊。-烏來區
  • 臺北市婦幼安全警示地點

    Payment instrument Free
    Update frequency Irregular
    「婦幼安全警示地點」係指近三年來曾有民眾通報或曾發生兩造當事人為陌生關係婦幼被害案件(包括刑法妨害性自主罪、第234條公然猥褻罪、第315條之1妨害秘密罪、性騷擾防治法第25條性騷擾罪等性別暴力犯罪)於道路、公園及廣場之公共場所、路段,經警察機關依轄區特性評估確為應提醒婦女、兒童及少年等弱勢族群注意安全,防範被害之地點。
  • 地區年齡性別統計表-侵襲性b型嗜血桿菌感染症

    Payment instrument Free
    Update frequency Irregular
    2003年起各地區、各年齡層、性別之病例數統計表(疾病名稱:侵襲性b型嗜血桿菌感染症,日期種類:發病日,病例種類:確定病例,感染來源:本土、境外移入)