Credence Cartridge Radiomics Phantom CT Scans

This collection consists of 17 CT scans of the Credence Cartridge Radiomics (CCR) phantom, which was designed for use in studies of texture feature robustness. The scans were acquired at four medical centers using each center’s chest protocol and were taken using GE (7 scans), Philips (5 scans), Siemens (2 scans), and Toshiba (3 scans) scanners. The CCR phantom has 10 cartridges, each with a unique texture, Fig 1. The first four cartridges are 3D printed ABS plastic with 20%, 30%, 40%, and 50% honeycomb fill, and they provide regular, periodic textures. The next three cartridges provide natural textures: sycamore wood, cork, and extra dense cork. A cartridges of shredded rubber particles provides textures similar to those of non-small cell lung cancer. The ninth cartridge is solid, homogenous acrylic and provides a minimal texture control. Finally, the 10th cartridge is 3D printed plaster has the highest electron density (400 – 600 HU) and is intended to more similar to bone.

In addition to the DICOM images for the 17 scans, this collection also contains two sets of contours as DICOM RT structure files. The first set provides 8x8x2 cm3 contours for each cartridge in each scan. The second set provides 16 adjacent 2x2x2 cm3 contours for each cartridge in each scan.

Researchers studying radiomics will be able to evaluate features for robustness across a variety of scanners. Features can be calculated using the researchers own software or third party software such as IBEX (imaging biomarker explorer). Related publications: http://journals.lww.com/investigativeradiology/Abstract/2015/11000/Measuring_Computed_Tomography_Scanner_Variability.3.aspx

The following paper was generated on different imaging modalities but the same phantom, this is a related but independent paper with a different set of authors: http://tinyurl.com/zm7tr7p

This data set was provided to TCIA by Authors: Mackin, Dennis; Fave, Xenia; Zhang, Lifei; Fried, David; Yang, Jinzhong; Taylor, Brian; Rodriguez-Rivera, Edgardo; Dodge, Cristina; Jones, Aaron Kyle; and Court, Laurence.

データとリソース

追加情報

フィールド
最終更新 12月 3, 2019, 14:19 (CST)
作成日 2月 14, 2019, 10:19 (CST)

推薦資料集:


  • 鐵道局基金會計月報

    Payment instrument Free
    Update frequency Irregular
    本資料集提供鐵道局基金會計月報相關資料
  • 110年10月花蓮縣土地增值稅徵收

    Payment instrument Free
    Update frequency Irregular
    花蓮縣110年10月土地增值稅徵收
  • 臺澳相互投資金額統計表

    Payment instrument Free
    Update frequency Irregular
    彙集臺澳相互投資數值
  • 違反董事會議事辦法常見缺失案例說明

    Payment instrument Free
    Update frequency Irregular
    違反董事會議事辦法常見缺失案例說明20131021
  • 電視使用行為及滿意度調查統計-視訊媒介使用情形

    Payment instrument Free
    Update frequency Irregular
    電視使用行為及滿意度調查統計-視訊媒介使用情形