需申請審核

Head-and-neck squamous cell carcinoma patients with 3D CT taken during pre-treatment, mid-treatment, and post-treatment (HNSCC-3DCT-RT)

Researchers will have the unique opportunity to visualize how head-and-neck squamous cell carcinoma (HNSCC) patients’ 3D CT image data changes with radiotherapy between pre-treatment, mid-treatment, and post-treatment. They will also have the advantage to receive additional information such as a) photon energy, b) number of arcs for volumetric modulated arc radiotherapy (VMAT) therapy, c) tumor volume and location, d) CT-to-density table, e) treatment related toxicities for parotid glands and oral cavity, f) patient age and weight, patient chemotherapy medication, g) prior surgery, h) performance status, i) histology, j) disease stage, k) number of targets, l) organs at risk, and m) other structures delineated on the CT image. This data collection contains three dimensional high-resolution (3D) fan-beam CT scans collected during pre-treatment, mid-treatment, and post-treatment using a Siemens 16-slice CT scanner with standard clinical protocol for 31 head-and-neck squamous cell carcinoma (HNSCC) patients. Patients underwent radiotherapy treatment to a total dose of 58-70 Gy, using daily 2-2.20 Gy, fractions for 30-35 fractions. The pre-treatment planning CT scans were performed with a median of 13 days (range: 2-27) before treatment, the mid-treatment CT was performed at fraction 17 (range: 8-26), and the post-treatment CT around fraction 30 (range: 26th fraction - 21 weeks post treatment). In addition to the imaging data, the data sets contain contours of anatomical structures for radiotherapy. The contours were generated by the attending radiation oncologists for treatment planning purposes, and subsequently treatment plans were generated with Eclipse® (Varian Medical Systems, Inc., Palo Alto, CA) treatment planning system. In addition to CT image data, included are: a) photon energy, b) number of arcs for volumetric modulated arc radiotherapy (VMAT) therapy, c) tumor volume and location, d) CT-to-density table, e) treatment related toxicities for parotid glands and oral cavity, f) patient age and weight, patient chemotherapy medication, g) prior surgery, h) performance status, i) histology, j) disease stage, k) number of targets, l) organs at risk, and m) other structures delineated on the CT image.

All patients were recruited according to the following criteria. Inclusion: i) patients had histologically confirmed head-and-neck tumors, ii) were treated with definitive radiation therapy or concurrent chemoradiation therapy, iii) patients treated with post-operative radiation therapy, for whom the gross tumor volume (GTV) or the resection cavity were visible on CT, such that it could be delineated as a target for radiotherapy, iv) patients were informed of the investigational nature of this study and were able to understand and to sign a written informed consent document.

Exclusion: i) pregnant or nursing women were not eligible to participate, ii) women of reproductive potential must have been offered a pre-treatment pregnancy test and informed of the need to practice an effective contraceptive method, iii) patients younger than 18 years, and iv) patients whose size and weight would not allow CT scanning.

資料與資源

額外的資訊

欄位
最後更新 十二月 3, 2019, 14:14 (CST)
建立 十月 16, 2018, 08:40 (CST)

推薦資料集:


  • 營造國際友善環境工作手冊

    付費方式 免費
    更新頻率 不定期
    推動營造國際生活環境系列政策之出版品,提供各級政府相關業務人員及一般有興趣之民眾查閱。
  • 金門縣海域觀光亮點資訊開放計畫-金城鎮

    付費方式 免費
    更新頻率 不定期
    金城鎮重要景點介紹
  • 臺北市政府消防局EOC開放資料專區(TEST)

    付費方式 免費
    更新頻率 不定期
    本資料為介接臺北市政府消防局EOC資料,每30分鐘更新一次資料,實際數據依檔案內介接網址為準 (新版)資料格式說明: https://drive.google.com/file/d/0ByxolD5lbGvMV0xuNzUzclBfdlE/view 資料格式說明:...
  • 新北市定量免疫法糞便潛血檢查醫事機構-新莊

    付費方式 免費
    更新頻率 不定期
    新北市定量免疫法糞便潛血檢查醫事機構-新莊
  • 新北市里長資訊-新莊區

    付費方式 免費
    更新頻率 不定期
    新北市全市1032里里長聯絡資訊-新莊區