Credence Cartridge Radiomics Phantom CT Scans

This collection consists of 17 CT scans of the Credence Cartridge Radiomics (CCR) phantom, which was designed for use in studies of texture feature robustness. The scans were acquired at four medical centers using each center’s chest protocol and were taken using GE (7 scans), Philips (5 scans), Siemens (2 scans), and Toshiba (3 scans) scanners. The CCR phantom has 10 cartridges, each with a unique texture, Fig 1. The first four cartridges are 3D printed ABS plastic with 20%, 30%, 40%, and 50% honeycomb fill, and they provide regular, periodic textures. The next three cartridges provide natural textures: sycamore wood, cork, and extra dense cork. A cartridges of shredded rubber particles provides textures similar to those of non-small cell lung cancer. The ninth cartridge is solid, homogenous acrylic and provides a minimal texture control. Finally, the 10th cartridge is 3D printed plaster has the highest electron density (400 – 600 HU) and is intended to more similar to bone.

In addition to the DICOM images for the 17 scans, this collection also contains two sets of contours as DICOM RT structure files. The first set provides 8x8x2 cm3 contours for each cartridge in each scan. The second set provides 16 adjacent 2x2x2 cm3 contours for each cartridge in each scan.

Researchers studying radiomics will be able to evaluate features for robustness across a variety of scanners. Features can be calculated using the researchers own software or third party software such as IBEX (imaging biomarker explorer). Related publications: http://journals.lww.com/investigativeradiology/Abstract/2015/11000/Measuring_Computed_Tomography_Scanner_Variability.3.aspx

The following paper was generated on different imaging modalities but the same phantom, this is a related but independent paper with a different set of authors: http://tinyurl.com/zm7tr7p

This data set was provided to TCIA by Authors: Mackin, Dennis; Fave, Xenia; Zhang, Lifei; Fried, David; Yang, Jinzhong; Taylor, Brian; Rodriguez-Rivera, Edgardo; Dodge, Cristina; Jones, Aaron Kyle; and Court, Laurence.

Data and Resources

Additional Info

Field Value
Last Updated December 3, 2019, 14:19 (CST)
Created February 14, 2019, 10:19 (CST)

推薦資料集:


  • 雲林管理處灌溉水質監測結果

    Payment instrument Free
    Update frequency Irregular
    工作站 監視點編號 監視點名稱 採樣日期 檢驗日期 水溫(℃)pH EC(μS/cm) SS(mg/L) Cl-(mg/L) SO42-(mg/L) NH4N
  • 高雄市稅捐稽徵處違章漏稅案件受理件數-108

    Payment instrument Free
    Update frequency Irregular
    違章漏稅案件受理件數
  • insight_test_8659

    Payment instrument Free
    Update frequency Irregular
  • 高齡人口統計資料

    Payment instrument Free
    Update frequency Irregular
    109年度花蓮縣社福相關資料
  • 台灣自來水公司近年漏水防治國際合作成果

    Payment instrument Free
    Update frequency Irregular
    提供本公司近年漏水防治國際合作成果相關資料