Credence Cartridge Radiomics Phantom CT Scans

This collection consists of 17 CT scans of the Credence Cartridge Radiomics (CCR) phantom, which was designed for use in studies of texture feature robustness. The scans were acquired at four medical centers using each center’s chest protocol and were taken using GE (7 scans), Philips (5 scans), Siemens (2 scans), and Toshiba (3 scans) scanners. The CCR phantom has 10 cartridges, each with a unique texture, Fig 1. The first four cartridges are 3D printed ABS plastic with 20%, 30%, 40%, and 50% honeycomb fill, and they provide regular, periodic textures. The next three cartridges provide natural textures: sycamore wood, cork, and extra dense cork. A cartridges of shredded rubber particles provides textures similar to those of non-small cell lung cancer. The ninth cartridge is solid, homogenous acrylic and provides a minimal texture control. Finally, the 10th cartridge is 3D printed plaster has the highest electron density (400 – 600 HU) and is intended to more similar to bone.

In addition to the DICOM images for the 17 scans, this collection also contains two sets of contours as DICOM RT structure files. The first set provides 8x8x2 cm3 contours for each cartridge in each scan. The second set provides 16 adjacent 2x2x2 cm3 contours for each cartridge in each scan.

Researchers studying radiomics will be able to evaluate features for robustness across a variety of scanners. Features can be calculated using the researchers own software or third party software such as IBEX (imaging biomarker explorer). Related publications: http://journals.lww.com/investigativeradiology/Abstract/2015/11000/Measuring_Computed_Tomography_Scanner_Variability.3.aspx

The following paper was generated on different imaging modalities but the same phantom, this is a related but independent paper with a different set of authors: http://tinyurl.com/zm7tr7p

This data set was provided to TCIA by Authors: Mackin, Dennis; Fave, Xenia; Zhang, Lifei; Fried, David; Yang, Jinzhong; Taylor, Brian; Rodriguez-Rivera, Edgardo; Dodge, Cristina; Jones, Aaron Kyle; and Court, Laurence.

Data and Resources

Additional Info

Field Value
Last Updated December 3, 2019, 14:19 (CST)
Created February 14, 2019, 10:19 (CST)

推薦資料集:


  • 109年高雄市應變中心開設0519豪雨人員傷亡、建物損失、搶救災民人數、出動救災人次、出動救災裝備統計

    Payment instrument Free
    Update frequency Irregular
    109年高雄市應變中心開設0519豪雨人員傷亡、建物損失、搶救災民人數、出動救災人次、出動救災裝備統計資訊
  • 109年7月花蓮縣土地增值稅徵收

    Payment instrument Free
    Update frequency Irregular
    109年花蓮縣土地增值稅徵收
  • 輔具服務單位

    Payment instrument Free
    Update frequency Irregular
    輔具服務單位
  • SPOD0005國科會新竹科學園區空氣品質數據

    Payment instrument Free
    Update frequency Irregular
    資料範圍:新竹園區、龍潭園區、竹南園區。 主要欄位說明:採樣時間、測站名稱、經度、緯度、一氧化碳、一氧化氮、二氧化氮、氮氧化物、臭氧、懸浮微粒、細懸浮微粒、二氧化硫、甲烷、非甲烷碳氫化合物、總碳氫化合物、風向、風速、溫度、相對濕度、空氣品質指標。
  • 金門縣公眾區免費無線上網熱點資料

    Payment instrument Free
    Update frequency Irregular
    金門縣公眾區免費無線上網(i-Taiwan)熱點資料