需申請審核

4D-Lung

This data collection consists of images acquired during chemoradiotherapy of 20 locally-advanced, non-small cell lung cancer patients. The images include four-dimensional (4D) fan beam (4D-FBCT) and 4D cone beam CT (4D-CBCT). All patients underwent concurrent radiochemotherapy to a total dose of 64.8-70 Gy using daily 1.8 or 2 Gy fractions. 4D-FBCT images were acquired on a 16-slice helical CT scanner (Brilliance Big Bore, Philips Medical Systems, Andover, MA) as respiration-correlated CTs with 10 breathing phases (0 to 90%, phase-based binning) and 3 mm slice thickness. 4D-FBCT images were acquired during simulation, prior to therapy, and used for therapy planning. In 14 of the 20 subjects, 4D-FBCTs were also acquired on the same scanner weekly during therapy. 4D-CBCT images were acquired on a commercial CBCT scanner (On-Board Imager™, Varian Medical Systems, Inc.). An external surrogate (Real-time Position Management, Varian Medical Systems, Inc.) was integrated into the CBCT acquisition system to stamp each CBCT projection with the surrogate respiratory signal through in-house software and hardware tools. Approximately 2500 projections were acquired over a period of 8-10 minutes in half-fan mode with half bow-tie filter. The technique was 125 kVp, 20 mA, and 20 ms in a single 360° slow gantry arc. Using the external surrogate, the CBCT projections were sorted into 10 breathing phases (0 to 90%, phase-based binning) and reconstructed with an in-house FDK reconstruction algorithm.

Audio-visual biofeedback was performed for all 4D-FBCT and 4D-CBCT acquisitions in all subjects. A single Radiation Oncologist delineated targets and organs at risk in all 4D-FBCT and a limited number of 4D-CBCT images, on all 10 phases per scan. Seven of the subjects had gold coils implanted as fiducial markers in or near the tumor.

For questions and information regarding this dataset, please contact Geoff Hugo, gdhugo@wustl.edu.

Data collection and analysis was supported by NIH P01CA116602.

資料與資源

此資料集沒有資料

額外的資訊

欄位
最後更新 十二月 3, 2019, 14:29 (CST)
建立 二月 14, 2019, 10:19 (CST)

推薦資料集:


  • 需申請審核

    2024年福爾摩沙衛星五號 L4 苗栗+台中

    付費方式 免費
    更新頻率 不定期
    此資料集為非公開資料,需由 TASA 進行資料審核。 欲申請者,請進入資料集後點選右上方「申請」填寫申請單;申請前請先登入系統。 若尚無平台帳號,請至 https://scidm.nchc.org.tw/user/register 進行註冊
  • 102年臺北市稅捐稽徵處電話問卷調查報告

    付費方式 免費
    更新頻率 不定期
    102年臺北市稅捐稽徵處電話問卷調查報告
  • 國際投資部位統計

    付費方式 免費
    更新頻率 不定期
    國際投資部位記載每年底我國對外金融總資產與總負債的存量。
  • 桃園市104年度建築物公共安全檢查稽查數量

    付費方式 免費
    更新頻率 不定期
    桃園市104年度建築物公共安全檢查稽查數量
  • 六輕相關計畫環境監測資料

    付費方式 免費
    更新頻率 不定期
    六輕相關計畫及雲林離島式基礎工業區開發計畫環境監測資料