需申請審核

Credence Cartridge Radiomics Phantom CT Scans

This collection consists of 17 CT scans of the Credence Cartridge Radiomics (CCR) phantom, which was designed for use in studies of texture feature robustness. The scans were acquired at four medical centers using each center’s chest protocol and were taken using GE (7 scans), Philips (5 scans), Siemens (2 scans), and Toshiba (3 scans) scanners. The CCR phantom has 10 cartridges, each with a unique texture, Fig 1. The first four cartridges are 3D printed ABS plastic with 20%, 30%, 40%, and 50% honeycomb fill, and they provide regular, periodic textures. The next three cartridges provide natural textures: sycamore wood, cork, and extra dense cork. A cartridges of shredded rubber particles provides textures similar to those of non-small cell lung cancer. The ninth cartridge is solid, homogenous acrylic and provides a minimal texture control. Finally, the 10th cartridge is 3D printed plaster has the highest electron density (400 – 600 HU) and is intended to more similar to bone.

In addition to the DICOM images for the 17 scans, this collection also contains two sets of contours as DICOM RT structure files. The first set provides 8x8x2 cm3 contours for each cartridge in each scan. The second set provides 16 adjacent 2x2x2 cm3 contours for each cartridge in each scan.

Researchers studying radiomics will be able to evaluate features for robustness across a variety of scanners. Features can be calculated using the researchers own software or third party software such as IBEX (imaging biomarker explorer). Related publications: http://journals.lww.com/investigativeradiology/Abstract/2015/11000/Measuring_Computed_Tomography_Scanner_Variability.3.aspx

The following paper was generated on different imaging modalities but the same phantom, this is a related but independent paper with a different set of authors: http://tinyurl.com/zm7tr7p

This data set was provided to TCIA by Authors: Mackin, Dennis; Fave, Xenia; Zhang, Lifei; Fried, David; Yang, Jinzhong; Taylor, Brian; Rodriguez-Rivera, Edgardo; Dodge, Cristina; Jones, Aaron Kyle; and Court, Laurence.

資料與資源

額外的資訊

欄位
最後更新 十二月 3, 2019, 14:19 (CST)
建立 二月 14, 2019, 10:19 (CST)

推薦資料集:


  • 南投縣娛樂稅稅源結構分析

    付費方式 免費
    更新頻率 不定期
    類別:電影、高爾夫球場、電子遊戲機、視聽視唱業、資訊休閒業、電動搖搖馬、娃娃機、機動遊藝樂園、其他、合計
  • 需申請審核

    CT Lymph Nodes

    付費方式 免費
    更新頻率 不定期
    This collection consists of Computed Tomography (CT) images of the mediastinum and abdomen in which lymph node positions are marked by radiologists at the National Institutes of...
  • 園區別營業額資訊

    付費方式 免費
    更新頻率 不定期
    提供歷年各園區營業額統計數及與上一年之比較資料
  • 新北市公園-蘆洲區

    付費方式 免費
    更新頻率 不定期
    新北市公園基本資料包含:名稱、所在區、地址、管理單位及聯絡電話-蘆洲區
  • 臺中市警察局102年10月份交通事故資料

    付費方式 免費
    更新頻率 不定期
    臺中市警察局102年10月份交通事故資料